Power And Sensor Connection ( 15 Vdc Sensors) With Optional Sps Module - VAT 650 Series Installation, Operating, & Maintenance Instructions

Dn 100-250 i.d. 4“ - 10”, pendulum control & isolation valve with cc-link interface
Table of Contents

Advertisement

2.6.5 Power and sensor connection ( 15 VDC sensors) with optional SPS module

[650 . . - . . A . - . . . . / 650 . . - . . C . - . . . . versions only]
Pins 4 and 8 must be bridged for operation!
An optional switch would allow for motor interlock
to prevent valve from moving.
Low range sensor may be connected
to sensor 1 or sensor 2 input.
Do configuration accordingly.
Note:
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources.
Connect the 15 VDC sensors at DB–15 female sensor connector exactly as shown in the drawing above.
Do not connect other pins, that may damage power supply or controller!
Connector: Use only screws with 4-40UNC thread for fastening the connectors!
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4" - 10"), CC-Link
280271EF
19/84
2012-10-02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents