Digital Read Out (Optional) - HARWI ORCA Series Manual

Table of Contents

Advertisement

DIGITAL READ OUT
RE-ADJUST THE REFERENCE POINT OF THE
MIDWAY FENCES
Re-adjust the reference point when bottom
supports are smoothened or when the
midway fences are smoothened.
Check the reference point when battery is
replaced.
Check if the reference point of the bottom
1
supports is correctly adjusted.
Disconnect the machine of the mains
2
supply.
Put the saw unit in horizontal position.
3
Press the F-button for 3 seconds, the
4
digital read out shows: ConF.
Press several times shortly the F-button
5
until the display shows P 24.
Press the F-button one more time.
6
Use the
and
button to change the
7
value to 000000.0
Press several times shortly the F-button
8
until the digital read out shows the
normal measuring again.
Position the saw blade on the midway
9
fences.
10 The digital display shows a value. Write
this value down on a piece of paper.
11 Press the F-button for 3 seconds, the
digital read out shows: ConF.
12 Press several times shortly the F-button
until the display shows P 24.
13 Press one more time the F-button, the
digital read out shows 000000.0
14 Use the
and
button to change the
value to the value that was written down
on the paper.
15 Press several times shortly the F-button
until the digital read out shows the
normal measuring again.
STANDARD VALUES
Press three seconds the F-button to check
the standard values. Press shortly the F-
button to go to the next value.
Designation
Saw direction
mm-inch /
Counting dir.
Decimal point
Factor
Reference ABS
Reference MF
Off-set value
Version
38
(OPTIONAL)
Display Programmed
value
ConF
0
P 01
01
P 03
1
P 08
1.0000
P 09
Ref value
P 24
Ref value
P 28
000003.2
P 99
0005.103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Orca 1850Orca 2150

Table of Contents