Description of the DESKLINE
DB5/DB6 system
®
Each DESKLINE
DB5/DB6 actuator is equipped with a motor and parallel/memory drive is ensured by means of software in
®
the CBD4/CBD5/CBD6 that also takes account of oblique load on the desk. Soft start and stop are also part of this software,
which ensures a soft start and stop when adjusting the desk.
Application of the DESKLINE
DB5/DB6 system:
®
Irrespective of the load the duty cycle 10% ~ 6 min./ hour or max. 2 min. at continuous use stated in the data sheets,
must NOT be exceeded as this will result in a superheating of the motor, the brake and the spindle nut. Exceeding the duty
cycle will result in a dramatic reduction of the life of the system.
The system must not be allowed to collide with and be blocked by an external object. In such a case the working parts of DB5/
DB6 can be damaged. If the system collides with an object e.g. If the desktop is stopped by a window ledge, then the system
should be examined to see as to whether the DB5/DB6 still functions correctly.
The DESKLINE
DB5/DB6 system range contains following products:
®
• 1 control box CBD4/CBD5/CBD6
• 1 single DB5/DB6 or 2, 3, or 4 parallel
• 1 exchangeable mains cable
• 1, 2, 3, or 4 motor cables
• 1 DP1U/DPF1M (if memory function is required) or 1 DPA/DPB/DP1K/DP1V/DPF1K (if only up/down is required.)
Page 9 of 28