Fitting The Sensor - Dräger Polytron 7000 Instructions For Use Manual

Transmitter for electrochemical sensors
Hide thumbs Also See for Polytron 7000:
Table of Contents

Advertisement

Fitting the sensor

1 Remove bayonet ring from transmitter, remove dummy plate.
Remove sensor from packaging.
Remove the short-circuit strap from the sensor (if it is fitted).
There is a coded connector on the back of the sensor. Place the sensor in the
opening with the connector at the back and the Dräger logo at the front.
Before plugging the connector in the socket, ensure that they are identically cod-
ed. Incorrect connection can damage the sensor!
Secure sensor in transmitter with bayonet ring.
Attention:
For use in Zone 22, tighten the locking screw (2 mm Allen screw) of the
sensor bayonet ring tight enough to ensure that the bayonet ring is
secured against unintended loosening.
If necessary, calibrate the sensor as described on page 42.
If pre-calibrated sensors are used, the alarm chain must be tested with, for exam-
ple, the bump test.
Electrical connections
Polytron
OK
1
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P3uP3fb