2.2. Wiring

PNE001Z is equipped with dual shielded RJ45 connectors. When you use PNE001Z with VF-S15, the
shielding of RJ45 connectors are connected to the grounding terminal of option adapter.
Cable specifications
• Minimum Cat 5e,
• Use equipotential bonding conductors,
• Connector RJ45, no crossover cable
• Shield: both ends grounded
• Twisted pair cable
• Maximum cable length = 100 m (328 ft)
The following table describes the pin layout of RJ45 connecter.
* Fix a cable so that a communication connector may be not taken the weight of wire.
Port L and Port R
8..................1
- 12 -
Pin
Signal
1
TD+
2
TD-
3
RD+
4
-
5
-
6
RD-
7
-
8
-