SureCross™ FlexPower™ Data Radio
Many of the parameters are configurable. The values in the tables represent factory defaults unless otherwise noted.
Radio
Range*
Transmit Power
Spread Spectrum Technology
Antenna Connector
Antenna Max. Tightening Torque
*
With standard 2 dB antenna. The range depends on the environment and line of sight. High-gain antennas are available to increase the range.
General
Power*
Power Consumption, 900 MHz
Power Consumption, 2.4 GHz
Mounting
M5 Fasteners Max. Tightening Torque
Case Material
Weight
Indicators
Switches
Display
Cable Glands Max. Tightening Torque
*
For European applications, power the DX80 from a Limited Power Source as defined in EN 60950-1.
Communications
Interface
Baud Rates
Data Format
Environmental
Environmental Rating**
Operating Temperature***
Operating Humidity
Radiated Immunity
Shock and Vibration
** Please refer to the SureCross™ DX80 Wireless I/O Network product manual, Banner p/n 132607, for installation and waterproofing instructions.
*** Operating the devices at the maximum operating conditions for extended periods can shorten the life of the device.
18
P/N 132031 rev. E

Specifications

900 MHz: Up to 9.6 kilometers (6 miles)
2.4 GHz: Up to 3.2 kilometers (2 miles)
900 MHz: 30 dBm Conducted
2.4 GHz: 18 dBm Conducted (≤ 20 dBm EIRP with standard 2 dB antenna)
FHSS (Frequency Hopping Spread Spectrum)
Ext. Reverse Polarity SMA, 50 Ohms
0.45 N•m (4 in•lbf)
+10 to 30V dc (For European applications: +10 to 24V dc, ± 10%) on the brown wire
3.6 to 5.5V dc on the gray wire
Gray wire (3.8V): 120 mW (low traffic) or 650 mW (high traffic)
Brown wire (12V): 230 mW (low traffic) or 900 mW (high traffic)
For low traffic applications, a slave device consumes 25% less power than a master device.
Gray wire (3.8V): 80 mW (low traffic) or 120 mW (high traffic)
Brown wire (12V): 200 mW (low traffic) or 250 mW (high traffic)
For low traffic applications, a slave device consumes 25% less power than a master device.
#10 or M5 (M5 hardware included)
0.56 N•m (5 in•lbf)
Polycarbonate
0.26 kg (0.57 lb.)
Two LED, bi-color
Two Push Buttons
Six Character LCD
0.56 N•m (5 in•lbf)
2-wire RS-485 or RS-232 (user selectable)
9.6k, 19.2k (default), or 38.4k
8 data bits, selectable parity (even, odd, or none), 1 stop bit
IEC IP67; NEMA 6
−40 to +85° C (Electronics); −20 to +80° C (LCD)
95% max. relative (non-condensing)
10 V/m, 80-2700 MHz (EN61000-6-2)
IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
Banner Engineering Corp. • Minneapolis, MN U.S.A
www.bannerengineering.com • Tel: 763.544.3164

Advertisement