Specifications; Banner Engineering Corp Limited Warranty - Banner DF-G1-NR-2M Quick Start Manual

Df-g1 expert dual display fiber optic light receiver
Table of Contents

Advertisement

DF-G1 Expert
Dual Display Fiber Optic Light Receiver
Value
PASS/FAIL
0 to 99%
FAIL
100 to 300%
PASS
300 to 600%
PASS
600% +
PASS
Percent Offset after SET
The Window, Dark, and Light SET methods will flash a % offset on the displays after a PASS or FAIL.
SET Result
PASS (with % Offset)
FAIL (with % Offset)
FAIL (without % Offset)
NOTE: For Window SET and Light SET, the maximum offset threshold percent is 90%.

Specifications

Light Detection Range
400 to 1100 nm
Supply Voltage
10 to 30 V dc Class 2 (10% max ripple)
Power and Current Consumption (exclusive of load)
Standard display mode: 960 mW, Current consumption < 40 mA at
24 V dc
ECO display mode: 720 mW, Current consumption < 30 mA at 24 V dc
Supply Protection Circuitry
Protected against reverse polarity, overvoltage, and transient voltages
Delay at Power Up
500 milliseconds max.; outputs do not conduct during this time
Output Configuration
1 current sinking (NPN) or 1 current sourcing (PNP) output, depending
on model
Output Rating
100 mA max. load (derate 1 mA per °C above 30 °C)
OFF-state leakage current: < 5 μA at 30 V dc
ON-state saturation voltage: NPN: < 1.5 V; PNP < 2 V

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following
the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture
which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty
does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
P/N 172436 Rev. C
Description
The difference of the taught conditions does not meet the required minimum
The difference of the taught conditions just meets/exceeds the required minimum,
minor sensing variables may affect sensing reliability
The difference of the taught conditions sufficiently exceeds the required minimum,
minor sensing variables will not affect sensing reliability
The difference of the taught conditions greatly exceeds the required minimum, very
stable operation
% Offset Meaning
Displays the % offset used for the SET method
Displays the minimum required % offset necessary to PASS the SET method
Presented condition cannot be used for the SET method
www.bannerengineering.com - tel: 763-544-3164
Output Protection
Protected against output short-circuit, continuous overload, transient
over-voltages, and false pulse on power up
Operating Conditions
Temperature: −10 °C to +55 °C (+14 °F to +131 °F)
Storage Temperature: −20 °C to +85 °C (−4 °F to +185 °F)
Humidity: 90% at +60 °C maximum relative humidity (non-
condensing)
Output Response Time
50 ms
150 ms
Temperature Drift
0.2% per °C
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear
polycarbonate cover
Environmental Rating
IEC IP50, NEMA 1
Certifications
Ind. Cont. Eq.
3TJJ
17

Hide quick links:

Advertisement

Table of Contents
loading