Clearing Stopped Documents In The Track Using The 'Smartclear' Function; Manually Removing Stopped Documents - Digital Check SmartSource Expert Micro Elite Installation And Operation Manual

Table of Contents

Advertisement

Installation & Operations Guide - SmartSource Expert Micro Elite
by application delays or other non-physical errors. Follow the instructions on the application screen to decide how to
handle the stopped document.

Clearing stopped documents in the track using the 'SmartClear' function

To remove a stopped document from the track, first use the 'SmartClear' function (see
above). This will cause the unit to drive the stopped document out of the track.

Manually removing stopped documents

If the stopped document is not ejected, then open the front and image covers (see
Expert Micro Elite
above) and remove the stopped document by pulling it parallel to the track, as shown below.
pulling the document straight up and out of the track.
Pull out stopped document from the front-
parallel to the track
June 2019
Pull out stopped document-open Image
cover & pull out parallel to the track
8227 6059-001
Using the power/start-stop
Basic layout of your SmartSource
Page 20 of 30