Commissioning
1.
Switch on the compressed air supply.
2.
Where applicable, switch on the material pressure pump or pressurised material container
for the spray medium.
3.
Point the hand-held spray gun at a test surface.
Fig. 4: Pull lever
4.
WARNING!
Sound pressure level
WARNING!
Risk of injury due to recoil forces during the activation of the hand-held spray
gun!
Start the spraying process by actuating the trigger ( Fig. 4/1).
5.
Adjust the spray pattern (
6.
End the spraying process by releasing the pull lever ( Fig. 4/1).
7.4
Adjusting the spray pattern
There are four different nozzle types:
200-0415 ■ 200-0416 ■ 200-0417 ■ 200-0418
Ä Chapter 7.4 'Adjusting the spray pattern' on page 23).