7.5.2 Long-term shut-down
Fig. 7: Pull lever
1.
Disrupt the spraying process by releasing the pull lever ( Fig. 7/1).
2.
Close the compressed air supply and the material supply. Switch off the material pressure
pump if necessary.
3.
Release the residual energy by actuating the pull lever ( Fig. 7/1).
Fig. 8: Drain screw
4.
DANGER!
Danger of death due to escaping pressure
If using a hand-held spray gun (item no. 200-0416 or 200-0418) with a flow pressure cup (
Fig. 8/3) or a hand-held spray gun (item no. 200-0415 or 200-0417) with a suction pressure
cup ( Fig. 8/1), turn the appropriate drain screw ( Fig. 8/2) until the pressure energy is
audibly released from the flow or suction pressure cup. Then close the drain screw again.
GB–26
Operating instructions
T-Dok-692-GB-Rev.0
mail@krautzberger.com, www.krautzberger.com