6.5 Configuring the VPPM-...C1
Editing the pressure range and the arrangement of the setpoint value display
1. In order to activate the EDIT mode, press the EDIT button.
Only with active security locking - [Lock] flashes:
2. Press the UP/DOWN button until the desired security code is set and confirm
by pressing the EDIT button.
[Out] flashes.
3. Press the UP/DOWN button until [In] flashes in the display, then press the
EDIT button.
[min] flashes.
Editing the pressure regulation range:
4. Set the minimum pressure value with the UP/DOWN buttons, then press the
EDIT button.
[max] flashes.
5. Set the maximum pressure value with the UP/DOWN buttons, then press the
EDIT button.
The current setpoint value display type flashes.
– Either [mA] or [V] flashes, depending on the variant of the VPPM-...C1
– or percent [%] flashes
– or [kPa], [psi] or [bar] flash, depending on the unit set in the SPEC menu.
Configuring the setpoint value display
6. Set the desired display type using the UP/DOWN buttons, then press the EDIT
button.
The VPPM-...C1 is then in the RUN mode again.
Fig. 19

Configuring the switching output (Out)

Warning
Depending on the functions of the machine/system, the manipulation of signal
states can cause serious injury to human beings and damage to property.
• Note that if the switching behaviour of the switching outputs is modified in
the EDIT mode, the new status will be effective immediately.
• Define the desired switching characteristics of switching output D3.
Switching points (SP... ) and hysteresis (Hy)
With setting SP.O.
p [bar]
U [V]
Fig. 20
Switching points (SP... ) and hysteresis (Hy) with NO setting (normally open
contact)
With threshold
value comparator setting
With window
comparator setting
Fig. 21
Hysteresis
Setpoint value
Actual value
SP.O. signal
OUT
1
Hy
0
SP
OUT
1
Hy
Hy
0
SP min.
SP max.
Switching points (SP... ) and hysteresis (Hy) with NC setting (normally closed
contact)
With threshold
value comparator setting
With window
comparator setting
Fig. 22

Configuring the switching output

1. In order to activate the EDIT mode, press the EDIT button.
Only with active security locking: [Lock] flashes.
2. Press the UP/DOWN button until the desired security code is set and confirm
by pressing the EDIT button.
[Out] flashes.
3. Press the EDIT button.
The current switching characteristic flashes.
4. Select the desired switching characteristic (threshold value/window compara-
tor or S.P.O.) with the UP/DOWN button and confirm with the EDIT button.
With switching function Threshold Value/Window Comparator:
[SP] or [SP] [
] flashes.
min
5. Set the switching point (SP or SP
with the EDIT button.
With "window comparator" switching function:
[SP] [
] flashes.
max
6. Set the switching point (SP
the EDIT button.
[HY] flashes.
7. Set the hysteresis (HY) with the UP/DOWN button and confirm with the EDIT
button.
[NO] or [NC] flashes.
8. Set the switching characteristic (NO/NC) with the UP/DOWN button and con-
firm with the EDIT button.
The VPPM-...C1 is then in the RUN mode again.
t
Fig. 23

Forcing the input

t
1. In order to activate the EDIT mode, press the EDIT button.
Only with active security locking: [Lock] flashes.
2. Press the UP/DOWN button until the desired security code is set and confirm
by pressing the EDIT button.
[Out] flashes.
3. Press the UP/DOWN button until [Force] flashes in the display, then press the
EDIT button.
[Force] flashes.
4. The set value can now be edited by pressing the UP and DOWN buttons.
Caution
Please note: the controller will apply the new set value immediately.
5. By pressing the EDIT button you can exit the Force mode. The analogue volt-
age and current values of the input still apply.
P
The VPPM-...C1 is then in the RUN mode again.
Fig. 24
P
OUT
1
Hy
0
OUT
1
Hy
0
SP min.
) with the UP/DOWN button and confirm
min
) with the UP/DOWN button and confirm with
max
P
SP
Hy
P
SP max.