Technical Data - ESAB Caddy Mig C200i Instruction Manual

Hide thumbs Also See for Caddy Mig C200i:
Table of Contents

Advertisement

3 TECHNICAL DATA

3
TECHNICAL DATA
Mains voltage
Permissible load at:
25 % duty cycle
60 % duty cycle
100 % duty cycle
Setting range
Open circuit voltage
Open circuit power
Efficiency at maximum current
Power factor at maximum current
Wire feed speed
Wire diameter:
Fe
Cored wire
Ss
Al
Max. diameter wire bobbin
Continual sound pressure at no-load
Dimensions l × w × h
Weight
Operating temperature
Transportation temperature
Enclosure class
Application classification
Welding torch
Cooling
Permitted load at 20 % duty cycle:
Carbon dioxide C0
2
Mixed gas Ar/C0
2
Self-shielded
Permitted load at 35 % duty cycle:
Carbon dioxide C0
2
Mixed gas Ar/C0
2
Self-shielded
Recommended gas flow
Wire diameter
Weight
0440 001 001
Mig C200i
230 V, 1 ~ 50/60 Hz
180 A
120 A
100 A
30 A - 200 A
60 V
15 W
82%
0.99
2.0 - 12.0 m/min
Ø 0.6 - 1.0
Ø 0.8 - 1.0
Ø 0.8 - 1.0
Ø 1.0
Ø200 mm
< 70 db
449 × 198 × 347 mm
12 kg
-10 to +40°C
-20 to +55°C
IP 23C
MXL 180
Air/shielding gas
200 A
180 A
120 A
180 A
150 A
100 A
8 - 15 I/min
0.6 - 1.0 mm
1.32 kg
- 8 -
© ESAB AB 2020

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents