Short Circuit rating F5 and F6 G - housing:
For 240 V Models:
„Suitable For Use On A Circuit Capable Of Delivering Not More Than 10000 rms Symmetrical
Amperes, 240 Volts Maximum, when Protected by J or RK5 Class, see instruction manual for
maximum fuse sizes".
For 480 V Models:
„Suitable For Use On A Circuit Capable Of Delivering Not More Than 10000 rms Symmetrical
Amperes, 480 Volts Maximum, when Protected by CC, J or RK5, see instruction manual for
maximum fuse sizes".
Branch Circuit Protection of inverters F5 and F6 G-housing:
UL 248 Fuses; Class RK5, J or CC as specified below:
Inverter model
F5/F6
14
15
14
15
16
17
18
(#) manufactured by Siba Sicherungen-Bau GmbH
"The Voltage Rating of the external Fuse(s) shall be at least equal to the input voltage of the
Drives"
"For installations according to Canadian National Standard C22.2 No. 14-13(#),
following cULus line Filters manufactured by Karl E. Brinkman need to be installed:
Inverter size KEB Filter Part No."
Inverter size
14F5, 14F6 (240 V)
14F5, 14F6 (480 V)
15F5, 15F6 (240 V)
15F5, 15F6 (480 V)
16F5, 16F6 (480 V)
17F5, 17F6 (480 V)
18F5, 18F6 (480 V)
Input Voltage
[V]
240 / 3ph
240 / 3ph
480 / 3ph
480 / 3ph
480 / 3ph
480 / 3ph
480 / 3ph
UL 248 Fuse
Class RK5 or J
[A]
50
70
30
40
50
60
70
KEB Filter Part No.
18E5 T60-1001
16E5 T60-1002
18E5 T60-1001
16E5 T60-1002
18E5 T60-1001
18E5 T60-1001
18E5 T60-1001
Annex
UL 248 Fuse
class CC
[A]
30
GB - 35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Combivert f6

Table of Contents