Figure 6.8: Example of Insertion Tool Use
6.7

Data Receiver Modules

LTC 8902 Series Video Output bays are supplied with LTC 8916/01 Data Receiver modules.
LTC 8903 Series Video Input bays are supplied with LTC 8918/01 Data Receiver modules.
Data Receiver Modules are installed into the right most slot (adjacent to the power supply) of
the matrix bays as follows:
Figure 6.9: Typical Data Receiver Module Insertion
6.8

LTC 8916/01 Data Receiver Modules

The LTC 8916/01 Data Receiver modules (installed in LTC 8902 Series bays) contain three (3)
8-position dip switches.
For system configurations of up to 2048 cameras and 512 monitors, , page 66 can be used as
a guide for setting the Data Receiver DIP switches. Otherwise, follow the procedure described
below.
Verify that switches located on dipswitch S1 are all OFF.
On dipswitch S2 of the LTC 8916/01, verify that switches from 1 to 4 are OFF. Switch 8
should be in the ON position. Switches 5 through 7 determine the monitor number range that
the bay will be used for and must be set according to , page 41.
5
OFF
OFF
OFF
OFF
Bosch Security Systems, Inc.
Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901
6
7
Monitor Range
OFF
OFF
1 to 64
OFF
ON
65 to 128
ON
OFF
129 to 192
ON
ON
193 to 256