en | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC
44
8901 Series CPU
Figure 6.10: Typical Video Output Module Insertion
The LTC 8934/00 Video Output Modules contain five (5) 8-position dip switches. DIP switch
S1001 is reserved and all switches should be left in the ON position.
Dip switches S1002, S1003, S1004, and S1005 are video termination switches for each of the
video bus inputs. All of these switches should be set to ON (terminated), the factory default
position. All LTC 8934/00 Video Output Modules are identical and can be swapped anywhere
within the bay without making any changes to the module.
6.11

LTC 8921/00 Video Input Modules

For the LTC 8903 Series Bays, termination switches(S1001 through S1004) on the LTC
8921/00 Video Input Modules must be set to the correct position prior to installation. Read
Termination Practices section prior to actually installing the Video Input Modules on these
systems. As shipped from the factory, all terminated switches are placed in the ON
(terminated) position.
It is helpful to locate and use one or more of the diagrams that best fits your system
configuration among , page 66 to , page 66 in this manual.
The appropriate number of Video Input Modules (LTC 8921/00) should be installed in the LTC
8903 Series main bay, starting with the left most slot. Each input module handles 32 inputs by
32 outputs.
Since the LTC 8903 Series supplies 64 outputs, two (2) LTC 8921/00 input cards are required
for each set of 32 cameras. Odd numbered slots provide video for monitors 1-32, and even
numbered slots provide video for monitors 33-64. If 32 or fewer monitors are being served by
the LTC 8903 Series bay, Video Input Modules are not required in the even numbered slots.
This concept is shown in , page 66, and examples of system configurations are shown in ,
page 66.
Cards in even numbered slots should have all termination switches set to OFF. If looping is
not being used, cards in odd numbered slots should have the termination switches set to ON
(see Termination Practices for more details).
Figure 6.11: Typical Video Input Module Insertion