Commissioning
4.6

Filter Settings

The following filter types can be used to enable filters in the signal path in order to adapt the
device to special applications. For the allocation of the different filters, please see the signal
graph above. The filter settings can be defined in the parameters "Filter Settings" as listed in
chapter "Parameter Table".
Filter Types
Butterworth lowpass
Butterworth highpass
Bessel lowpass
Bessel highpass
Tschebyscheff lowpass
Tschebyscheff highpass
Table 4.6
Filter Order
Off
st
1
nd
2
rd
3
Table 4.7
Cut-off frequency
1 ... 65000 mHz
Table 4.8
18
ID
0
1
2
3
4
5
ID
0
1
2
3
ID
1 ... 65000