Troubleshooting
External Fault Error — This message is triggered by a device external to the MilTouch™ ma-
chine. This error usually originates with the chemical supply system.
Emergency Stop Error — The emergency stop switch (locking push button) is locked. The
controls are disabled and the machine remains idle until the switch is unlocked. To unlock the
emergency stop switch, turn the switch clockwise.
Too Many Recycles — Due to an unbalanced load, the machine has performed the maximum
of five extract cycles. The controller will skip to the next step in the formula. If the current (im-
balanced) extract step is the final step in the formula, the formula will end.
Control on Clean Side — This message indicates the controls on the clean (discharge) side
are enabled on barrier machines.
Loadcell Comm Failure — This error occurs on weighing machines with a load cell. The con-
troller cannot receive data, or receives an unexpected data stream from the load cell.
Level Too Low — After the flow meter fills the machine to the configured minimum (low)
water level, this error occurs if the water level drops below half of the minimum water level and
remains below half of the minimum water level for 30 continuous seconds.