Filling By Simultaneously Use Of Chemfiller And External Filling Device - Hardi COMMANDER TWIN FORCE Series Instruction Book

Table of Contents

Advertisement

9. When the spray liquid is well agitated, turn handle on the pressure
SmartValve towards "Spraying" position. Keep P.T.O. engaged so the
spray liquid is continuously agitated until it has been sprayed on the
crop.
Filling by simultaneously use of ChemFiller and External Filling
Device
As the water from the External Filling Device is transferred directly to
the ChemFiller Vortex nozzle and Container Cleaning, the advantage
in using this filling method is that the ChemFiller always will be
clean and safe after use.
1. Turn the handle at the suction SmartValve towards "suction from
External Filling Device". Turn Pressure SmartValve towards "Main tank"
and the AgitationValve towards "Agitation". Other valves closed.
2. Connect external suction hose to the External Filling Device coup-
ler.
3. Engage the pump and set P.T.O. speed at 540 r/min or 1000 r/min
(depending on pump model).
4. Open the ChemFiller suction valve and the External Filling Device
valve.
5. Open ChemFiller lid and engage the hopper rinsing device by
opening the ChemFiller Vortex nozzle.
6. Meanwhile keeping an eye to main tank level indicator, then mea-
sure the correct quantity of chemical and fill it into the hopper.
7. The chemical is being transferred to the main tank. If not then
partly close the External Filling Device valve to increase vacuum at
the ChemFiller suction. This could be the case if filling from high pla-
ced external tank or when having syphon effect.
8. When the chemical container is empty it can be rinsed by the
Chemical Container Cleaning device. Close ChemFiller Vortex nozzle
and place the container over the multi-hole nozzle and press the
lever behind the ChemFiller.
9. Close External Filling Device valve when main tank is full.
10. Close the ChemFiller suction valve and the ChemFiller lid again.
11. When the spray liquid is well agitated, turn handle on the pressu-
re SmartValve towards "Spraying" position. Keep P.T.O. engaged so
the spray liquid is continuously agitated until it has been sprayed on
the crop.
ATTENTION! The scale in the hopper can only be used if the sprayer is parked at level ground! It is recommended
to use a measuring jug for best accuracy.
5 - Operation
5.9

Advertisement

Table of Contents
loading