6 - Maintenance

1000 hours service - Hydraulic oil change

The hydraulic oil is changed every 1000 hours or once a year - whi-
chever comes first. The hydraulic oil change is best done when the
fan has been working for at least one hour and the oil has reached
working temperature.
Firstly, the used oil must be drained from the tank; this is done by
the tap (A).
1. Remove the cap from the tap (A) and fit a hose connection + tube
(1/2") to the tap (A).
2. Open the ball-valve on the tap and lead the waste oil, via the
tube, into an appropriate container.
3. Close the ball-valve and fit and tighten the cap to the tap (A)
again when all the waste oil has been drained.
Additionally, new oil is filled into the tank.
1. Clean the area around the oil filling cap (B).
2. Unscrew the filling cap and fill the tank with fresh, clean hydraulic
oil until the level is between min. and max. on the level glass (C). The
tank contains approx. 45 l. Regarding oil specification - see section
on "Lubricants".
3. Fit the filling cap again.
Note local legislation regarding disposal of waste oil.

1000 hours service - Gearbox oil change

The first gear box oil change must be done after 50 hours, then
every 1000 hours or once a year - whichever comes first. The gear
box oil change is best done when the machine has been working
for at least one hour and the oil has reached working temperature.
1. Clean the area around filling plug/breather (A), dip stick (B) and
drain plug (C) thoroughly.
2. Place a tray under the drain plug to retain the waste oil.
3. Unscrew the filling and drain plugs and drain the gear box oil.
4. Refit the drain plug using a new seal - retighten.
5. Fill with fresh, clean oil until the level reaches the sight glass.
Approx. oil quantity: 0.4 l (14.1 fl.oz.). Regarding oil quality, see sec-
tion on "Lubricants".
6. Refit the dip stick and filling plug - retighten.
Disposal of waste oil must only be carried out in accordance with
local legislation.