Filling Chemicals By Hardi Chemfiller Without Optional Valves; Filling Chemicals By Hardi Chemfiller With Optional Valves - Hardi COMMANDER TWIN FORCE Series Instruction Book

Table of Contents

Advertisement

5 - Operation

Filling chemicals by HARDI ChemFiller without optional valves

1. Fill the main tank at least 1/3 with water (unless something else is
stated on the chemical container label).
2. Turn the handle at the suction SmartValve towards "suction from
Main tank". Turn Pressure SmartValve towards "Main tank" and the
AgitationValve towards "Agitation".
3. Engage the pump and set P.T.O. speed at 540 r/min or 1000 r/min
(depending on pump model).
4. Open ChemFiller lid and engage the hopper rinsing device by
opening the ChemFiller Vortex nozzle.
5. Measure the correct quantity of chemical and fill it into the hop-
per. The chemical is being transferred to the main tank.
6. If the chemical container is empty it can be rinsed by the
Chemical Container Cleaning device. Place the container over the
multi-hole nozzle and press the lever behind the ChemFiller.
7. Close ChemFiller Vortex nozzle again when the hopper is rinsed.
8. Close the ChemFiller lid again.
9. When the spray liquid is well agitated, turn handle on the pressure
SmartValve towards "Spraying" position. Keep P.T.O. engaged so the
spray liquid is continuously agitated until it has been sprayed on the
crop.

Filling chemicals by HARDI ChemFiller with optional valves

1. Fill the main tank at least 1/3 with water (unless something else is
stated on the chemical container label).
2. Turn the handle at the suction SmartValve towards "suction from
Main tank". Turn Pressure SmartValve towards "Main tank" and the
AgitationValve towards "Agitation". Other valves closed.
3. Engage the pump and set P.T.O. speed at 540 r/min or 1000 r/min
(depending on pump model) and open the ChemFiller suction
valve.
4. Open ChemFiller lid and engage the hopper rinsing device by
opening the ChemFiller Vortex nozzle.
5. Measure the correct quantity of chemical and fill it into the hop-
per. The chemical is being transferred to the main tank.
6. If the chemical container is empty it can be rinsed by the
Chemical Container Cleaning device. Place the container over the
multi-hole nozzle and press the lever behind the ChemFiller.
7. Close ChemFiller Vortex nozzle again when the hopper is rinsed.
8. Close the ChemFiller suction valve and the ChemFiller lid again.
5.8

Advertisement

Table of Contents
loading

Table of Contents