Machine and Engine Faults
Machine Faults
Machine Faults
Fault
Fault Title
ID
B1027
Speed
Increase/Decrease
Switch Broken
B105D
Cutting unit
Raise/Lower Switch
Broken
C1013
Engine Run Output -
Short to Battery
Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
Machine faults are generated by the TDM display/controller to identify an
electrical system malfunction (fault) that occurs during machine operation. The
fault IDs conform to SAE J2012 standards. When a fault occurs, the bi-color
LED on the TDM display/controller panel will flash red and a code for the active
fault will appear along the bottom of the TDM display/controller screen. If more
than one fault is active, their codes will scroll across the bottom of the TDM
display/controller screen one-by-one. Depending on the severity of the fault,
a STOP icon may also be displayed.
Recent faults can be viewed via the TDM display/controller screen. A code
appears after each fault indicating which controller generated the fault. For
example: C14C5:T1 is a PTO fault generated by the T1: TDM
Fault
Condition/Circuit
Description
The speed
increase and
speed decrease
Inputs are active
at the same time.
The cutting unit
raise and deck
lower Inputs
are active at the
same time.
Low current
detected on the
engine run output
circuit. Indicates
a short to a high
(+) source.
Additional Notes
Service Actions
Speed
1.
Test the speed increase/decrease switch.
increase/decrease
2.
Check the wire harness connectors
is disabled.
(P100, P106) for damage or corrosion
and clean or repair if necessary.
3.
Check the circuit wiring.
Cutting unit
1.
Test the cutting unit raise/lower switch.
raise/lower is
2.
Check the wire harness connectors
disabled.
(P100, P33) for damage or corrosion and
clean or repair if necessary.
3.
Check the circuit wiring.
The short could be
1.
Check the wire harness connectors for
to battery voltage
damage or corrosion and clean or repair
or to another signal
if necessary.
that is in a high (+)
• Model 31900/01 (P100, P19, P202,
state.
• Model 31902/03 (P100, P19, P53, P55,
2.
Test the engine run output circuit wiring.
3.
Test the engine run output circuit
components.
• Model 31900/01 (start interlock relay,
• Model 31902/03 (start interlock relay,
4.
Swap the TDM controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
Page 3–5
Troubleshooting: Cutting Unit (or attachment) Problems
P203)
P01)
fuel pump, fuel solenoid)
fuel pump, alternator)