Glow Plug Switch (Model 31900, 31901, 31907 And 31909) - Toro Groundmaster Series Service Manual

Table of Contents

Advertisement

Glow Plug Switch (Model 31900, 31901, 31907 and 31909)

Testing the Glow Plug Switch
Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
POSITION
CLOSED
CIRCUITS
2 + 3, 5 + 6
OFF
ON
2 + 1, 5 + 4
The glow plug switch is located on the operator's console. The glow relay and
the glow plugs are energized as long as the front of the switch is depressed.
1. Park the machine on a level surface, lower the cutting unit (or attachment),
engage the parking brake, set the key switch to the O
the key from the key switch.
2. Disconnect the battery negative (-) cable at the battery; refer to
and Installing the Battery (page
3. Remove the operator's console covers; refer to
Operator's Console Covers (page
4. Disconnect the wire harness connector from the switch and remove the
switch from the console if necessary. Check the switch and the harness
connector for damage or corrosion and clean or repair if necessary.
5. Use a multimeter (ohms setting) and the preceding table to determine
whether continuity exists between the various terminals for each switch
position.
6. Replace the switch if necessary.
7. If the switch tests correctly and a circuit problem still exists, check the wire
harnesses; refer to
8. Install the switch and connect the wire harness after testing.
9. Install the console covers.
10. Connect the battery negative (-) cable at the battery.
6–64).
7–23).
Appendix A (page
A–1).
Page 6–25