Vent Configurations - Travis Industries DVL EmberGlo GSR2 Insert Owner's Manual

Table of Contents

Advertisement

Installation (for qualified installers only)

Vent Configurations

Inlet & Exhaust Re-Line
Factory Built (Metal) Wood-
Burning Fireplace
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
CAUTION: The "Exhaust Only Re-line" is not covered under the appliance safety standard (ANSI
) used in the safety certification of this appliance. The Omni safety certification does not apply to this
2.33
installation. Before installing the appliance using this method, contact the Authority Having Jurisdiction to
determine if this installation is acceptable in your area. This type of installation requires a minimum chimney
cross-section of 48 square inches.
© Travis Industries
Inlet
Recommended Block-Off
Plate (must be non-
combustible - metal /
insulation). Prevents odors
from chimney entering
room.
Masonry Fireplace
9/17/2020 - 1536
Exhaust Only Re-Line
Exhaust
Any cracks or
damage inside the
chimney must be
repaired.
A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(must be non-combustible -
metal / insulation)
17
Z21.88 CSA
DVL EG GSR2