Vent Requirements - Travis Industries DVL EmberGlo GSR2 Insert Owner's Manual

Table of Contents

Advertisement

14

Vent Requirements

Travis Industries stocks 2 vent kits
for this insert. Each kit includes 30'
of 3" & 4" vent, 4 clamps, and
termination. The flashing is 18"
(458mm) by 18" (458mm).
The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent
gas appliance must use its own separate vent system.
Installation instructions for DuraVent may be found at www.duravent.com.
Make sure the exhaust pipe on the heater connects to the exhaust portion of the cap. The
illustrations below show how the flex liners should be attached.
The exhaust vent must reline the entire length of the chimney and terminate above the chimney top
Be careful not to crimp or rupture the liner when bending it into chimney offsets
When installed, the vent must meet all of the vent manufacturer's requirements
Use the following vent:
4" UL 441 or 1777 Gas Liner for Exhaust, 3" UL 441 or 1777 Gas Liner for Air Inlet
Duravent Chimney Liner Termination (use one of the three listed below):
-- Prairie Cap with Flashing (included in kit shown above)
-- High-Wind Vertical Cap with 3" & 4" Co-Linear Connection
-- 3" & 4" Co-Linear to 6-5/8" Co-Axial Adapter, Flashing, & High-Wind Vertical Cap
Drafting Performance
This direct vent appliance requires natural draft to operate (similar to a wood stove or other heating appliance). The
draft can be adjusted using the included restrictor. The restrictor settings detailed in the manual should be followed
(variations may occur depending upon installation parameters).
Many factors may negatively influence the draft of the appliance. Travis Industries will not be responsible for improper
draft due to factors such as trees, hills, buildings, obstructions, excessive wind, extreme hot or cold outdoor
temperatures, restrictive vent terminations, or influence from mechanical systems.
© Travis Industries
Installation (for qualified installers only)
Max. Ht. 40' (12.2M)
Min. Ht. 16' (5M)
96200331 – Prairie 3"/4"
Max. 4'
(1.2M)
offset
9/17/2020 - 1536
96200340 - High Wind 3"/4"
DVL EG GSR2