Technical data

Mains supply .................... 230 V~, 50 Hz
Device fuse, internal ........ 1,6 A, T (slow)
Operational force .......................... 550 N
Nominal load ................................. 150 N
Power consumption with
nominal load ................................ 150 W
Idle current (Stand-by) ..................... 7 W
Protection class ........ For dry rooms only
Speed with nominal load ...... > 100 mm/s
Run time limit ................................... 80 s
Max. stroke ............................... 2540 mm
Flush height ................................. 35 mm
Radio control ............................. 433 MHz
Permissible ambient
temperature ................ -20 °C bis + 50 °C
Hand-held transmitter range* ... 15 - 50 m
Illumination ............................ max. 40 W
Transmitter battery ........... 12 V, Typ 23 A
Obstruction safety device setting .. 150 N
Max. number of cycles per hour
(with nom. load) .................................. 20
Max. number of cycles per hour
without interrupt (with nom. load) .......... 8
* The hand-held transmitter range might
be significantly reduced by external dis-
turbances under certain circumstances.

Noise emission level

Topmost noise pressure level: <70dB (A)
50
Search/elimination of
malfunctions
Only qualified electricians may
carry out work on the electrical equip-
ment. Disconnect mains plug before
removing drive cover.
Drive does not run at all:
1. Check fuses of the building
2. Check fuse of motor control
3. Are the bridged western plugs cor-
rectly plugged in at the external termi-
nals [30] (5 = green, 6 = yellow)?
4. Have mains supply checked by quali-
fied electrician.
Drive runs faulty:
1. Is the sled snapped in [33]?
2. Is the drive belt properly adjusted
[16]?
3. Is the door step/way frozen?
4. Does the drive switch or switch off
during run? Obstruction safeguard is
activated. Check and adjust door.
Carry out basic setting [35].
5. Does the program run not work? Re-
set electronic control into default set-
ting and learn newly [35].
Drive cannot be operated by hand-
held transmitter:
1. Does the LED on the hand-held trans-
mitter flash? Renew battery [55].
2. Does the red LED (3) on the drive
head not light during activation of
hand-held transmitter? Reset learned
radio commands [46] and newly learn
hand-held transmitter [41] once more.
3. Reception level too low: Check anten-
na connection, if necessary, install ex-
ternal antenna [64].
Drive cannot be operated by the
wall-fitted button:
Check wall-fitted button and control lead.
Obstruction safeguard does not
work:
Reset electronic control and subse-
quently carry out basic settings (learning
runs) [35].
Malfunction during self-test:
After each motor run and every 2 1/4
hours in idle state, a self-test of the con-
trol is carried out. Malfunctions that have
been detected during self-test are signal-
ised by flashing of the green
LED „Power".
Flashing Cause of malfunction
signal
2x
Malfunction in main memory
3x
Impermissible motor current
values
4x
Safety output of control de-
fective
5x
Thyristor-measurement -
values impermissible
6x
motor-relays measurement
values impermissible
7x
Program run faulty
8x
Memory for learned values
faulty
If a malfunction occurs during self-test,
the control blocks, and after 60 s another
test is automatically carried out. If dur-
ing repeated test a malfunction is also
detected, the control is reset and re-
mains blocked.
If the control is blocked during self-test
due to a detected malfunction, the elec-
tronic control has to be reset and the ba-
sic settings have to be carried out once
more. If the malfunction occurs again,
the control has to be replaced by a spe-
cialist.

Maintenance

Monthly:
• Check obstruction safeguard: The
drive direction must change if the
door closing edge meets a 50 mm
high obstacle that stands on the
ground.
• Check mountings of the door drive at
ceiling and wall.
• Check emergency stop for function.
• Check functioning of escape door
safeguard (if present).
Yearly:
• Maintain door according to manufac-
turer data.
• Grease or oil joints of pushing bar.
• Check tension of drive belt, if required
tighten it [16].