1-channel operation
[42] First button is learned.
Multi-channel operation
[43] 2-channel operation: learn first,
second or arbitrary button.
[44] 3-channel operation: learn first,
second, third or arbitrary button.
[45] 4-channel operation: learn first,
second, third and fourth button.
Reset of all learned radio com-
mands (if needed only)
[46] Activate „Program" button (2) at
least 5 seconds long. The red LED
(3) flashes then for 2 seconds
quickly and goes out – now the re-
set procedure (duration about 5
seconds) is finished. Any learned
hand-held transmitters are reset.

[47] Terminal configuration

Terminals 1 - 16 of the built-in ter-
minal strip are connected by default
(=standard connection).
Terminals for additional connections
15
Additional lamp 230 V AC,
L-switched, fused
16
Additional lamp 230 V AC, N
17
Antenna for radio
18
Earth connection for antenna

Additional settings

In the manufacturers default setting the
soft run in closing direction is switched
on and the pre-warning time of drive
lamp is switched off. The soft run in
opening direction is set as standard and
cannot be changed.
If needed, the following additional set-
tings are possible:
Switch on/off soft run
[48] Activate „Program" button (2) once,
the red LED (3) flashes once. Push
„Impulse" button (1) once, the red
LED (3) flashes twice. Activate
„Program" button (2) once, the soft
run in closing direction is switched
off.
In order to switch the soft run back
on, repeat the aforesaid working
steps.
Switch on/off pre-warning time
By switching on the pre-warning
time first only the drive lamp is lighting
with each control-device impulse, only
four seconds later the motor run is start-
ed.
[49] Activate „Program" button (2) once,
the red LED (3) flashes once. Push
„Impulse" button (1) twice, the red
LED (3) flashes three times. Acti-
vate the „Program" button (2) once,
the pre-warning time will be
switched on. In order to switch the
pre-warning time back off, repeat
the aforesaid working steps.
Setting automatic closure
Only authorized specialists are
allowed to carry out this setting.
The automatic closure is a control func-
tion, which runs the door automatically
from opened position back into closed
position. The closing time is freely ad-
justable (from 2 s to maximal 8.5 min-
utes). The automatic closure is switched
off in the default setting; the jumper is in
„SL1" position [50].
The operation with automatic
closure is permitted only if additional
safety equipment (light barrier/optical
sensor/safety strip) is installed. The
setting is carried out with connected
mains power. The drive cover has to
be removed for carrying out the set-
ting, see [57].
[51] Set automatic closure by jumper
(19):
Run door into opened position. Af-
ter reaching the desired open time,
plug the jumper into „AZ" position,
the door runs into closed position.
The set time remains saved. Put
drive cover back in place.
The set automatic closure remains
active even after reset of the control.
Learning runs are delayed accordingly.
Additional illumination
Only a qualified electrician may
perform the connection of an addi-
tional illumination.
In addition to the drive light (40 W) an
additional illumination of max. 60 W (no
fluorescent tube or energy saving lamp)
might be connected.
[47] Connect additional lamp at termi-
nals 15 and 16 (light) parallel to
the drive lamp.
Change drive direction
Changing the drive direction is re-
quired for double-doors and, if neces-
sary, for lateral-sliding doors.
[52] Unlock western plug (5) with green
bridge and pull off.
[53] Activate the „Program" button
once, the red LED flashes once.
Push „Impulse" button (1) 5 times,
the red LED flashes 6 times. Acti-
vate „Program" button once, the
change of drive direction is carried
out and the electronic control is re-
set.
[54] Plug western plug with green
bridge (5) back in. Carry out basic
setting (carry out learning runs),
see [35].
Additional safety
connections
[30] In delivery state, bridged western
plugs (5=green, 6=yellow) are
plugged in the external connec-
tions „Emergency stop" (5) and
„Safety strip/light barrier" (6).
Terminal „Emergency stop" (5)
An emergency equipment (slip-door
safeguard or emergency-stop pushbut-
ton) can be connected to this input:
[54] Snap off, pull off and store western
plug with green bridge. Install
emergency stop equipment and
connect by means of western plug.
Check for function: If the emergen-
cy stop equipment is activated dur-
ing the door run, the motor has to
stop immediately.
Terminal „Safety strip/optical sen-
sor/light barrier (SE/LS)" (6)
A safety strip or an optical sensor (only
in combination with a corresponding ex-
ternal evaluation equipment) or a light
barrier might be connected to this input.
[54] Snap off, pull off and store western
plug with yellow bridge. Connect
safety strip, optical sensor or light
barrier according to the relevant
enclosed instructions for installa-
tion. Check for function: If the in-
stalled safety device is operated
while the gate is closing, the gate
must stop and allow the object to
move. The next impulse moves the
gate into the open position.