Pressure Gauge 0 986 610 805 And 0 986 613; Mounting Support 0 986 611 - Bosch Denoxtronic 1.1 Product Description

Test device adblue supply module
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
en
22 | Denoxtronic 1.1 | Devices and components
3.5
Pressure gauge 0 986 610 805 and
0 986 613 103
i
The pressure gauge 0 986 610 805 is part of case
0 986 610 800 (Denoxtronic-Set 1).
The pressure gauge 0 986 613 103 is not included
in the scope of delivery and must be ordered sepa-
rately.
The pressure gauges are used for AdBlue delivery
modules to test various system operating pressures, the
functioning of the switchover valve and suction.
!
The pressure gauges are designed specifi-
cally to test AdBlue delivery modules of the type
Denoxtronic 1.1. Use of other pressure gauges is not
allowed.
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 1.1.
Fig. 5:
Pressure gauge 0 986613 103 and 0 986 610 805
1
Pressure gauge 0 986 613 103 (test of AdBlue circuit)
2 Pressure gauge 0 986 610 805 (test of air circuit)
i
The measuring accuracy of the pressure gauges
must be tested regularly by a certified inspection
authority. This is the responsibility of the user.
i
If the pressure gauge is defective, it must be re-
placed with a new one.
|
1 689 989 403
2019-03-01
3.6

Mounting support 0 986 611 249

The mounting support (fig. 6, item 1) is fastened to the
front left of the prepared working surface of the test
device 0 986 613 880 (4 M8 screws).
The rod 0 986 610 981 (fig. 6, item 3) is inserted into
the round receptacle of the mounting support and
clamped tight. The base plate 0 986 613 865 (fig. 6,
item 2) is fixed to the rod with two screws (M10).
The AdBlue supply module is attached to the base plate
for testing and repairs. The AdBlue supply module can
be moved into the corresponding position for use by
turning the rod and the lever on the mounting support
during testing and repairs.
!
When loosening and turning the rod on the mount-
ing support, always hold the base plate or the
AdBlue supply module with one hand to prevent
uncontrolled tipping.
Fig. 6:
Mounting support 0 986 611 249 on the test device
0 986 613 880
1 Mounting support 0 986 611 249
2 Base plate 0 986 613 865
3 Rod 0 986 610 981
i
Detailed instructions on use and handling can be
found in the separate ESI[tronic] repair instructions
Denoxtronic 1.1.
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents