6.4
Gas manifold 0 986 610 970
i
A function test of the safety valves (2 each) in the
gas manifold must be performed annually.
The test is carried out without an AdBlue delivery
module connected.
Fig. 16:
Gas manifold 0 986 610 970
1 Plug connector for connecting the forming gas 5 container
2
Switching lever
3 Membrane grommet
4 Pressure gauge
5 Connection for the bleeding pipe
Procedure:
1. Connect the gas manifold to a gas cylinder contain-
ing nitrogen (fig. 16, item 1).
2. Put the lever on the gas manifold in the <supply
module> position.
3. Set the pressure-reducing valve of the gas container
to a test pressure of 11 bar.
4. Open the shut-off valve of the gas container briefly,
and close it again. If necessary, repeat the process
several times.
 Safety valve 1 in the gas manifold must open.
The function is indicated by the sound of gas es-
caping. The pressure gauge of the gas manifold
must indicate a pressure drop to 10 bar.
5. To relieve pressure in the gas manifold, put the lever
from the <supply module> position to the <gas out-
let> position and back repeatedly until the pressure
gauge no longer indicates any pressure at the gas
manifold.
6. Disconnect the gas cylinder from the coupler
(fig. 16, item 1).
"
This completes the function test of safety valve 1.
7. Unscrew the connecting piece with bleeder hose
(fig. 16, item=m 5).
Robert Bosch GmbH
Maintenance | Denoxtronic 1.1 | 29
8. Screw in appropriate coupler (e. g. KS3-1/4-A, from
Festo, not included in scope of delivery).
9. Connect the gas manifold to a gas cylinder contain-
ing nitrogen (fig. 16, item 5).
10. Put the lever on the gas manifold in the <gas outlet>
position.
11. Set the pressure-reducing valve of the gas container
to a test pressure of 11 bar.
12. Open the shut-off valve of the gas container briefly,
and close it again. If necessary, repeat the process
several times.
 Safety valve 2 in the gas manifold must open.
The function is indicated by the sound of gas es-
caping. The pressure gauge of the gas manifold
must indicate a pressure drop to 10 bar.
13. To relieve pressure in the gas manifold, put the lever
from the <gas outlet> position to the <supply mod-
ule> position and back repeatedly until the pressure
gauge no longer indicates any pressure at the gas
manifold.
14. Disconnect the gas cylinder from the coupler
(fig. 16, item 5).
15. Unscrew the coupler and screw in the connecting
piece with bleeder hose (fig. 16, item 5) again.
"
This completes the function test of safety valve 2.
i
After the function test, it is necessary to check the
gas manifold for leaks. The procedure for this can be
found in the separate ESI[tronic] servicing instruc-
tions Denoxtronic 1.1, in the section "Leak check-
ing" under "Checking the operating fluid circuit for
leaks".
!
A defective gas manifold must not be re-used.