6 Installation and Commissioning
6.2

Installing the software (download)

Table 6-2
No.
16.
17.
6.3

Commissioning

Table 6-3
No.
18.
19.
20.
21.
22.
23.
Note
If there are any errors when loading the hardware configuration with
SITOP PSU8600, do a reset to factory settings.
Shutdown IPCs in the SITOP PSU8600 Buffer Mode
Entry ID: 109737962,
V1.2,
Download the
"109737962_Shutdown_IPC_ PSU8600_in_Puffermode.zip" example project in
entry ID
109737962
and unzip it in a folder of your choice.
Start the TIA Portal.
Open the "Shutdown_IPC_PSU8600_in_Puffermode" example project.
Click "Devices and network" in the project navigation to open the network view.
Go to the device view of the SITOP PSU8600 and the IPC by double-clicking the
left mouse button.
Adjust the IP address of the controller (CPU 1507S), WinCC (WinCC RT Adv)
and SITOP PSU8600 (psu_1) via the "Properties >Device interface > Ethernet
addresses" tab of the respective device.
This is only necessary, if you want to use different IP addresses.
Then adjust the access address for the web server of the SITOP PSU8600. The
instruction for it can be found in chapter
Compile the hardware configuration and download it into the devices.
Compile the program of the controller and the one for the visualization and down-
load it into the devices.
10/2017
Action
Action
5.5.
33