3 Basics
For the communication in the network, the basic device has a Profinet interface
that is equipped with two ports. The connection to a controller is from one of the
two ports either directly, or through a network switch that is connected with the
network of the controller.
Over the network, the parameters of the SITOP modules can be read out or con-
trolled and subsequently visually displayed.
For this purpose, the Siemens AG offers ready-made faceplate or communication
blocks for various controllers and WinCC (TIA Portal) software. They can be found
in the entry with entry ID 102379345.
By changing the firmware of the SITOP PSU8600 from 1.0.0 to 1.1.0, the internal
Note
data structure has changed. Make sure to download the correct library.
The download page for the firmware update can be found in the entry with entry
ID 102295547.
The basic device can be updated via direct connection from 1.0.0 to 1.1.0. The
CNX and BUF modules can also be dragged up directly via network from 1.0.0 to
1.1.0.
The hardware settings of the outputs are done on the front side of the module. Use
the TIA Portal for the configuration of the software. You have to slide the "REN"
DIP switch to the right, in order to enable the remote access.
Note
If the outputs are switched off manually via buttons 1-4 on the front side, remote
access is no longer possible. Switch the inputs on again by clicking the buttons
again, to re-enable the remote access.
In order for the SITO PSU8600 to be configurable in the TIA Portal, it has to be
added to the hardware product tree in the TIA Portal. To do this, use the appropri-
ate hardware support package (HSP file). You can find it, together with the installa-
tion manual, in the entry with entry ID 102254062.
In addition, the SITOP PSU8600 offers a web server that can be enabled via the
"WEN" DIP switch (for basic devices with product state (PS) 1 and firmware update
1.1.0 "FUNC"). Enabling takes place by moving to the position on the right.
Further functions and information for the SITOP PSU8600 can be found in the re-
spective manuals.
Manual SITOP PSU8600 power supply - basic devices with four outputs,
entry ID:
Manual SITOP PSU8600 power supply - basic devices with one output,
entry ID:
Shutdown IPCs in the SITOP PSU8600 Buffer Mode
Entry ID: 109737962,
V1.2,
105867947
109482936
10/2017