Installation And Commissioning; Installing The Hardware - Siemens SITOP PSU8600 Manual

Shutdown ipcs in the buffer mode
Hide thumbs Also See for SITOP PSU8600:
Table of Contents

Advertisement

6 Installation and Commissioning

Installation and Commissioning
6
6.1

Installing the hardware

The figure below shows the hardware configuration of the application.
Figure 6-1
Siem ens
O.K.
MAN
Pr ofinet
40A/4x10A
SF
RUN
P1
P2
3
1
2
ON/OFF/RST
Par alell
1
2
3
~400
M
X1
Table 6-1
No.
9.
10.
11.
12.
13.
14.
15.
Shutdown IPCs in the SITOP PSU8600 Buffer Mode
Entry ID: 109737962,
V1.2,
O.K.
40A/10s
4
4
PROFINET
0V
24V
Configure the IPC and the SITOP PSU8600 as described in chapter
Set the ON/OFF switch of the IPC to "off" and connect the IPC477D on output 1
of the SITOP PSU8600.
Connect the mains plug with an external voltage supply.
Note:
The switch can also be connected to one of the outputs of the SITOP PSU8600.
However, first of all the hardware configuration has to be loaded.
Connect the SITOP PSU8600, the network switch, the IPC447D, as well as the
development computer via Profinet.
Note: Connection without network
Connect the Ethernet cable with the "X2" network connection of your IPC. Con-
nect the other end with the network connection of your development computer.
Connect the Ethernet cable with the "X1" network connection of the
SITOP PSU8600. Connect the other end with the "X1" network connection of the
IPC.
Set the ON/OFF switch to position "on".
Switch on the input voltage of the SITOP PSU8600.
Start the development computer.
10/2017
Software Controller
HMI
Connection
S7-1507S
0V
X2
24V
X1
PROFINET
PROFINET
TIA
PROFINET
Action
Visualization
WinCC
Advanced
5.1
and
0
.
32