The temperature value belonging to 20 mA
Any value may be assigned to it within the temperature
interval displayable on the display [Default factory setting:
600.0 °C]
Averaging number (Averaging Number)
The displayed measurement result is generated as the
average of several measurements. The number of
measurements can be defined here.
By increasing this number the display stability increases too,
but the signal settling time becomes lower.
[Default factory setting: 8]
Display refresh time (Display Refresh)
The instrument performs cca. 15-16 measurements in each
seconds. It's too fast to see the changing of the
measurement value.
Here you can define the time periods by which the
instrument displays the new measurement values.
[Default factory setting: 0.5 sec]
The submenu that contains the test programs (Test)

Display test (Test: LCD)
Checking if the display works well.


,
Output.)
Putting the status of the limit outputs on the display and
changing them, irrelevant to their operating mode. Checking
the current output.
Changing the User Code (User Code)
The new User Code must be typed in twice, in order to
avoid any typing errors. The mnemonic
warns you to type the code for the second time, after you
have typed it once. If the two codes are not identical with
each other, the mnemonic
the display, and the instrument exits the menu item.
Make sure not to forget the User Code, otherwise a new
one can be defined only if you enter the menu by a
Supervisor Code [Default factory setting: 000]
Output test (Test: Output, Test: ANalog

(Bad Code) appears on
DT9502

(Re-Type)
20171205-V3