CopperLink Model CL1300 User Manual
•
Isolation: 500 VDC
•
Environment: 0–40°C; 5–95% relative humidity, non-condensing
CAUTION
1. Plug the DC power converter (see
page 28)
2. Connect the DC power converter's red and black wires to the 36–60 VDC power source.
Go to section
"Ethernet Extender Status LEDs"
CL1300R Series
The CL1300R comes standard with an AC switching power supply or an internal DC power converter.
AC power supply
The CL1300R comes standard with an AC power supply:
•
There is one fuse in the equipment rated at 250V, 500 mA, 2 sec.
•
Rated voltage: 5 VDC
•
Rated current: 1 A DC
•
Output from power supply: 5 VDC, 2A
•
Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
Do the following:
1. Plug the AC switching power supply (see
(see
figure 17
on page 31)
Connecting Power
The external DC adapter shall be a listed limited power source
that incorporates a disconnect device and shall be positioned
within easy reach of the operator. The interconnecting cables
shall be rated for the proper voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability.
figure
15) barrel jack into the CL1300 Power port (see
Figure 15. DC Power Converter (p/n 48V-PSM5)
on page 32.
figure
16) terminal block plug into the CL1300R terminal block
2 • Installation
figure 14
on
29