Block Functions - GE AV-300i User Manual

Hide thumbs Also See for AV-300i:
Table of Contents

Advertisement

1.1.2 Block Functions

Here is an example referring to the setting of a digital signal (Ramp output = 0) and of an analog signal (Speed
ref 1).
Digital signal
Let's consider a section of the Ramp Block.
In Ramp funct src menu, the source Ramp output = 0 allows the output of the RampBlock to be set to zero. By
editing (for example via the keypad by pressing enter) the source Ramp output = 0, the pick-list of the possible
signal sources of control is displayed.
The selected signal on the source, will be enable the Ramp output = 0 function.
The Ramp funct cfg menu configures the block parameters. The Ramp funct mon display the signal state.
RAMP CONFIG / Ramp function / Ramp funct src
Ramp output=0
............
RAMP CONFIG / Ramp function / Ramp funct cfg
Ramp shape
............
RAMP CONFIG / Ramp function / Ramp funct mon
Ramp out mon
.........
N
!
OTE
The points ............, refer to other possibilities parameters in the menus.
AV-300i Version 2 User's Guide
The following commands are available in
the source Ramp output=0 (it is standard connected to Null):
One
Null
DI 1 monitor
............
DI 0X monitor
B0 W0 decomp
............
The Ramp shape configuration allows to select the Ramp:
Linear
S-Shaped
It is possible to monitor:
Ramp out mon
Ramp cmds mon
............
—————— Function Description ——————
it connects the signal to One, Active
it connects the signal to Zero, Non-active
it connects the signal to the standard digi
tal input 1, being active or non-active is a
function of the digital input state
............
it connects the signal to the expanded dgt 0 input
it connects the signal to a digital bit de
rived from a complete word. For more
detail on this feature, refer to the 2.6.6
'chapter.
............
it sets the Linear Ramp
it sets the S Ramp
Output Ramp monitor
Ramp Block command monitor
............
Ch.1