Motopotentiometer Block (Moto Pot) - GE AV-300i User Manual

Hide thumbs Also See for AV-300i:
Table of Contents

Advertisement

Multi speed src
Mlt spd 0 src
Mlt spd s 0 src
Mlt spd s 1 src
Mlt spd s 2 src
Multi speed cfg
Mlt spd 0
Mlt spd 1
Mlt spd 2
Mlt spd 3
Mlt spd 4
Mlt spd 5
Mlt spd 6
Mlt spd 7
Multi speed mon
Mlt spd 0 mon
Mlt spd sel mon
Mlt spd out mon

1.8.5 Motopotentiometer Block (Moto Pot)

The Motopotentiometer Function is always active.
Furthermore, through the Motopot up src and Motopot down src sources it is possible to select the origin of the
Speed increase and decrease and of the command signals.
The Block offers also the possibility to invert the output reference. The Motopot invers src source selects the
inversion command.
The Speed Preset source, Motopot preset src, allows to select the Preset command. Such function can activate
a series of settings active on the input and/or output reference.
In the Block configurations it is possible to set, with Motopot lower lim and Motopot upper lim, the speed upper
and lower limit (in rpm and standard configured with 0 and 1000).
The Motopotentiometer acceleration and deceleration ramps are independent from those of the Ramp Block.
This Block, therefore, with Motopot acc dtl spd/time and Motopot dec dtl spd/time, allows to set the
Motopotentiometer Ramp.
Motopot init config allows to set the function stating the Motopotentiometer reference value when the Drive is
started. This parameter is selected among:
·
Power off
·
Zero
·
Lower limit
·
Upper limit
Furthermore, Motopot preset cfg states the function of the Preset command. It is possible to select:
·
None
·
Input = 0
·
Input = low lim
·
Input & ref = 0
AV-300i Version 2 User's Guide
Mlt spd 0 source reference
Bit 0 source for the selection of the active Multi spd reference
Bit 1 source for the selection of the active Multi spd reference
Bit 2 source for the selection of the active Multi spd reference
Speed 0
Speed 1
Speed 2
Speed 3
Speed 4
Speed 5
Speed 6
Speed 7
Speed 0 monitor
Active selection monitor
Monitor for the multispeed Block output
value at the turning off
zero rpm
Lower limit value
Upper limit value
no operation
the input state is set at zero
it sets on the input the speed lower limit
it sets at zero the input and reference state
—————— Function Description ——————