1.3 DRIVE INITIALIZATION (STARTUP - SETUP MODE)

This menu heading covers:
·
Selection of the regulation mode.
The drive can control the motor in three different ways:
V/f (VF), Field Oriented (FOC) and Sensorless vect (SLS).
The three methods are completely independent.
With such a condition each regulation mode can be configured differently from all the others.
·
Switching to the Setup mode.
With this mode it is possible to set the Drive and motor data and, if required, to start the process for the motor
data automatic measuring. The measured data can be stored in a file (Setup 0 or 1 or 2 or 3) via the save
setup command. In this way the detected data can be used during the automatic calculation of the Flux and
Current loop gains.
·
Automatic calculation of the flux and current loop gains according to the performed measuring processes
(load setup).
·
Setting of the information about:
-maximum speed
-encoder features, if used.
-Parameters of the I2t protections.
-Configuration of the V/f mode.
·
Database storage.
The setting of the above-mentioned features changes the relationships among the different parameters. As a
consequence, after changing the parameters belonging to this menu, it is necessary to store the whole data-
base via the save config command.
Such settings can be changed only with a disabled drive. While in this operation mode (Configuration)
the data updating on the terminal strip and on the option cards is stopped.
After downloading drive parameters from a file, or entering the STARTUP MENU through the keypad, the drive
restart is only permitted after:
a)cycling drive power
or:
b) when commands select = Terminal level, cycling input DI0, when commands select = Terminal edge, cycling input
DI0, and the digital input selected by Term strstp src, when commands select = Digital level, cycling the digital signals
selected by Digital strstp src and Digital enable src when commands select = Digital edge, cycle input DI0 or the digital
input Digital enable src (if not selected to ONE), and the digital signal selected by Digital strstp src

1.3.1 Selection of the Regulation Mode (Regulation Mode)

It allows to select the desired regulation mode.
After choosing the setting, the Drive carries out the restart phase by setting the selected regulation mode.
Description:
STARTUP
Regulation mode
Regulation mode
Select new mode
Save config ?
Ch.1
28
GEH-6641E