Pid Output Block (Pid Output) - GE AV-300i User Manual

Hide thumbs Also See for AV-300i:
Table of Contents

Advertisement

PD control src
PID PD enab src
PDGP ref src
PD control cfg
PD P1 gain %
PD D1 gain %
PD P2 gain %
PD D2 gain %
PD P3 gain %
PD D3 gain %
PDGP tran21 hthr
PDGP tran32 lthr
PDGP tran21 band
PDGP tran32 band
Int PDGP ref
PD der filter
PD control mon
PID PD out mon
PD P gain mon
PD D gain mon
PDGP ref mon

1.15.6 PID Output Block (PID Output)

This Block gathers the following signals:
·
Feed forward
·
PI block output
·
PD block output
As stated before, the FeedForward signal is multiplied by the PI Block output. It is possible to obtain different
effects according to this signal configuration.
The signal of the PD Block, on the contrary, is subtracted. In the Block configurations it is possible to select the
output as Bipolar or Multipolar (only for positive values) via an internal selector. On the Block output it is
possible to find a direct output, PID out, and an output with a configurable gain, PID outs.
The Block outputs are:
Description:
APPL FUNCTION
APPL FUNCTION
AV-300i Version 2 User's Guide
PD section enabling source
Gain adaptive source
P gain segment 1
D gain segment 1
P gain segment 2
D gain segment 2
P gain segment 3
D gain segment 3
Segment transition point from 1 to 2
Segment transition point from 2 to 3
Width of the transition band from 1 to 2
Width of the transition band from 2 to 3
Adaptive signal. Internal value
Derivative filter
Output correction value
Monitor for the P gain in use
Monitor for the D gain in use
Value of the present adaptive signal
· PID out mon
· PID outs mon
PID
PID output
PID output cfg
PID out sign
PID out gain
PID output mon
PID out mon
PID outS mon