The Speed 0 signal, Speed is zero, becomes active when the motor speed is lower than the Spd 0 speed
thr threshold. The signal "Spd is zero delay" is delayed by Spd 0 spd delay.
The Reference 0 signal, Ref is zero, becomes active when the speed reference connected to Spd 0 ref src
is lower than the Spd 0 ref thr threshold. The signal "Ref is zero delay" is delayed by Spd 0 ref delay.
On the Spd 0 ref src source it is possible to select the following signals:
·
Null
·
Ramp ref
·
Speed ref
·
Int spd 0 ref
Description:
SPEED CONFIG
SPEED CONFIG SAVE PARAMETERS
The Speed 0 Block is shown in the figure below.
Spd 0 ref src
Sbk P gain out
Sbk I gain out
Ch.1
102
zero
Ramp Block reference
Speed Block reference
internal value (it can be set in the configurations)
Spd 0 logic
Spd 0 logic src
Spd 0 ref src
Spd 0 logic cfg
Spd 0 enable
Int spd 0 ref
Spd 0
Spd 0
Spd 0 speed thr
Spd 0 spd delay
Spd 0 ref thr
Spd 0 ref delay
Spd 0 logic mon
Spd is zero
Ref is zero
Spd is zero dly
Ref is zero dly
InUse SpdP gain%
InUse SpdI gain%
SPEED
Norm
Gain
Spd=0
&
Ref=0
Sal
Gain
—————— Function Description ——————
GEH-6641E
P gain
I gain
>>Spd 0 P gain<<
>>Spd 0 I gain<<
Spd 0 speed thr
Ref=0
Spd 0 spd delay
Spd 0 ref thr
Spd 0 ref delay
Spd is zero
Ref is zero
Spd is zero dly
Ref is zero dly
InUse SpdP Gain%
InUse SpdI Gain%