1.3.2.2 Loading of the Setup Settings (Load Setup)

In order to be used by the Drive, the performed SETUP has to be loaded.
The "Load Setup" function allows to load the desired Setup file. It also carries out the calculation of the gains
of the regulation system.
Description:
STARTUP
Startup config
Load setup
Select setup ?
Save config ?

1.3.2.3 Speed Scale (Full Scale Speed)

It allows to set the speed normalization value. In other words, what rpm is 100% speed.
(See chapter 1.1.3 Signal Normalizations)
Description:
STARTUP
Startup config
Full scale speed
save config ?

1.3.2.4 Encoder Configuration (Encoders Config)

The function allows to configure, on the regulation card, some standard encoder inputs identified as "std" and
some expanded encoder inputs identified as "exp", which can be obtained using the expansion option card.
The Spd fbk sel src source allows to select the origin of a command encoder signal. It has connected Int spd
fbk sel through which it is possible to switch the feedback between the Encoder sta and the Encoder exp.
The command can be activated only with a Field Oriented mode.
The Index Storing function is available for positioning applications to detect the zero cam position (see the
paragraph below).
Description:
STARTUP
Startup config
Encoders config
Speed feedback
Int spd fbk sel
Spd fbk sel src
Std enc type
Std enc pulses
Std dig enc mode
AV-300i Version 2 User's Guide
it allows to load the saved setup
it selects the setup to be loaded (setup 0-1-2-3)
normalization value of the Drive speed
—————— Function Description ——————
Ch.1
31