Chapter 5 Frame Editor
Remark
Note1] If mode change is written, communication of RS-232C/RS-422 channel is disconnected for approx.
1 second to convert operation into newly changed mode and then is automatically operated in
changed mode after mode change is completed.
6) If the message below is shown, the mode switch of Cnet I/F module is not No.9 online mode. Change mode
switch of Cnet I/F module to No.9 online mode, reset PLC and execute again from No. (1).
7) If the message below is shown, version of Cnet I/F module is below Ver.2.0 and online mode change is
unavailable.
8) The changed mode is saved in flash memory of Cnet I/F module as kept even if powered off.
9) Operation mode in online mode set is valid only in online mode. If mode switch is selected in off-line mode
from 0 to 7, the operation mode is decided according to each mode switch.
10) Operation mode of Cnet module can be also read via Frame Editor even though Cnet module is not in
online mode. Select Read button with slot number and connection stage set to local in online mode change
menu as below.
[Note1]
5-37