ELECTRO FREEZE Soft Serve Models SLX400, SLX400E, SLX500
14
Trouble Shooting Tables
PROBLEM
Unit operates
1.
long or
continuously.
2.
3.
4.
Discharge
1.
pressure too
high.
2.
3.
4.
5.
6.
7.
Discharge
1.
pressure too low.
2.
Noisy
1.
compressor.
2.
44
PROBABLE CAUSE
Dirty condenser.
Shortage of refrigerant.
Moisture in system.
Compressor failing.
Water hose kinked or pinched. (water
cooled models)
Water turned off or defective water
regulating valve. (water cooled models)
Restricted water cooled condenser.
(water cooled models)
Dirty air condenser. (air cooled models)
Unit location too warm (air cooled
models)
Refrigerant overcharge.
Air in system.
Water regulating valve open too wide.
(water cooled model)
Shortage of refrigerant.
Tubing rattles.
Compressor spring broken internally.
(continued)
1.
Have condenser cleaned by your
Electro Freeze distributor.
2.
Contact your Electro Freeze Distributor
for service.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
1.
Move freezer and adjust hose so it is not
pinched or kinked.
2.
Turn on water, or contact your Electro
Freeze Distributor for service.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
5.
Contact your Electro Freeze Distributor
for service.
6.
Contact your Electro Freeze Distributor
for service.
7.
Contact your Electro Freeze Distributor
for service.
1.
Contact your Electro Freeze Distributor
for service.
2.
Contact your Electro Freeze Distributor
for service.
1.
Contact your Electro Freeze Distributor
for service.
2.
Contact your Electro Freeze Distributor
for service.
REMEDY
184599