14
Trouble Shooting Tables
PROBLEM
Dispensed
1.
product too soft.
2.
3.
Product
1.
Product too cold.
dispenses
slowly out of
dispensing
head.
2.
Dispensing speed adjustment bolt too far
down.
3.
Wrong rotation on beater.
Dispensed
1.
product too
hard.
2.
3.
184599
ELECTRO FREEZE Soft Serve Model SLX400, SLX400E, SLX500
PROBABLE CAUSE
Dirty or blocked condenser, restricted
air flow.
Component failure.
Leak in refrigeration system resulting in
little or no refrigeration.
Controls are set too cold.
Plunger switch electrically or
mechanically stuck closed.
Low suction pressure.
(continued)
1.
Unblock condenser or have cleaned by
your Electro Freeze distributor.
2.
Contact your local service company.
3.
Contact your local service company.
1.
Check product temperature. Should be
17° to 19°F (-8 to -7°C). See
Troubleshooting Table - Dispensed
product too hard.
2.
Contact your Electro Freeze distributor
for service.
3.
Have an electrician correct rotation to
clockwise as viewed from the front of the
freezer.
1.
Contact your Electro Freeze distributor for
service.
2.
Contact your Electro Freeze distributor for
service.
3.
Contact your Electro Freeze distributor for
service.
REMEDY