8.2
Disassembly Instructions
It is important that the freezer be disassembled, washed, lubricated and sanitized
before operation. For maximum life on moving parts, disassemble and sanitize at
the end of every day of operation.
Figure 8-2
to Section 11, Closing Procedures, 11.2
Draining Product.
by lifting up and swinging the bottom out and
down.
gently pull the dispensing head (1)
straight out.
184584
ELECTRO FREEZE Soft Serve Models SLX400, SLX400E, SLX500
To avoid electrical shock or contact with moving parts, make
sure the control pad is "OFF" and that the power switch is "OFF".
1. If there is product in the freezer, refer
2. Remove plunger rods (6, figure 8-2)
3. Remove the hand knobs (8) and
CAUTION
4. Remove the beater shaft (1, figure 8-
3) from each cylinder. Then remove breaker
bar (1), scraper blades (3) and shaft seal
(3,4) from the beater shafts. Remove the cup
seals (4) from the washer (5) on the shaft
seal assembly.
— continued