4
Virtual Quality Management System (VQM)
Terminology (continued)
Temp. Comp.: .................... Temperature comparison, utilized when the slope feature is
Temperature Offset: ........... A function that allows temperature adjustment to the
U.I./ User Interface: ........... The board that lies directly behind the membrane switch on
184584
ELECTRO FREEZE Soft Serve Models SLX400, SLX400E, SLX500
turned on. It prevents the system from seeing the slope
temperature curve until a determined temperature is reached.
Once that temperature has been reached then the system
will examine the curve and shut down if necessary.
Temp. Comp. Range: -10 to 15°F
operator. Adjustable from 1-9 and 5 being neutral/no change,
Lower than 5= colder and greater than 5=warmer
the front panel. This board houses the LED screen that
displays the menus and operations. The membrane switch is
connected to this board via a ribbon cable. This board also
has its own software.
9