ELECTRO FREEZE Soft Serve Models SLX400, SLX400E, SLX500
14
Trouble Shooting Tables
PROBLEM
Unit does not
1.
operate.
2.
3.
4.
5.
Leakage of mix
1.
or water from
drain tube to drip
tray.
2.
3.
Compressor
1.
Faulty contactor.
does not
operate or
operates
2.
Disconnected or broken wire in switch.
improperly.
40
PROBABLE CAUSE
Freezer unplugged.
Fuse or breaker blown at main
disconnect.
Off on high pressure cut-out control.
Off on low pressure cut-out control.
Disconnected or broken wire in electrical
circuit.
Damaged beater shaft seal or installed
improperly.
Beater shaft pitted or damaged where
o-ring rides.
Beater shaft end play not set properly.
(continued)
1.
Plug in freezer.
2.
Make sure your freezer is connected to a
separate circuit independent from any
other electrical equipment. Have
technician check fuse or breaker size and
check voltage; if not within 10% of
nameplate rating call power company.
3.
Refer to Troubleshooting Table –
Discharge pressure too high.
4.
Contact your Electro Freeze distributor for
service.
5.
Contact your Electro Freeze distributor for
service.
1.
Replace cup seals on washer. Install
properly.
2.
Replace beater shaft.
3.
Contact your Electro Freeze distributor for
service.
1.
Contact your Electro Freeze Distributor
for service.
2.
Contact your Electro Freeze Distributor
for service.
REMEDY