14
Trouble Shooting Tables
PROBLEM
Compressor
1.
Low line voltage.
does not start
– hums
intermittently
(cycling on
overload).
2.
Improperly wired.
3.
Open starting capacitor or current relay.
4.
High discharge pressure.
Poor or slow
1.
product
recovery.
2.
3.
Beater motor
1.
does not
operate.
2.
3.
4.
5.
6.
184599
ELECTRO FREEZE Soft Serve Model SLX400, SLX400E, SLX500
PROBABLE CAUSE
Dirty or blocked condenser, restricted
air flow – high ambient temperature.
Defective condenser fan motor.
Component or compressor failure.
Head assembly is not installed.
Magnetic head switch defective.
Loose connection in control circuit.
Open starter coil.
Faulty capacitor assembly. (Single
phase only.)
Faulty beater motor.
(continued)
1.
Ask power company to check voltage,
increase voltage to not less than 10%
below data plate rating or install
transformer. Have electrician check for
inadequate wire size.
2.
Contact your Electro Freeze distributor for
service.
3.
Contact your Electro Freeze distributor for
service.
4.
Contact your Electro Freeze distributor for
service.
1.
Have condenser cleaned by your Electro
Freeze distributor; lower ambient
temperature.
2.
Contact your Electro Freeze distributor for
service.
3.
Contact your Electro Freeze distributor for
service.
1.
Install head assembly.
2.
Contact your Electro Freeze Distributor
for service.
3.
Contact your Electro Freeze Distributor
for service.
4.
Contact your Electro Freeze Distributor
for service.
5.
Contact your Electro Freeze Distributor
for service.
6.
Contact your Electro Freeze Distributor
for service.
REMEDY
43