Sears GT Series Installation Instructions Manual page 33

Geothermal
Table of Contents

Advertisement

...............
_os s i,,bl!_Ca_u,,s
_...........
Checks ancl;;;;;;co_recti,o
n
ENTIRE
UNIT
Power Supply Off
DOES NOT R UN
Blown F use
Voltage Supply
Low
Thermostat
BLOWER
Thermostat
OPERATES
BUT
COMPRESSOR Wiring
DOES NOT
Safety Controls
Compressor
overload open
Compressor
motor grounded
Compressor
windings Open
UNIT O FF O N
Discharge
HIGH P RESSURE pressure
toohigh
CONTROL
Refrigerant
charge
High pressure
Suction pressure
toolow
Refrigerant
charge
Low pressure
switch
UNITOFF
ON LOW
PRESSURE
CONTROL
Apply p ower, close d isconnect
Replace
fuse orreset circuit breaker. Check forcorrect fuses
Ifvoltage isbelow minimum v oltage specified onunit d ata plate,
contact local power company.
Set t he fan to"ON", the fan should r un. Set t hermostat
to"COOL" and
lowest temperature
setting, theunit s hould runinthe cooling mode
(reversing
valve e nergized).
Set umt t o"HEAT" and thehighest
temperature
setting, theunit s hould r un intheheating mode. Ifneither
theblower orcompressor
runinall t hree cases, thethermostat
could
bemiswired orfaulty. To ensure miswired orfaulty t hermostat
verify 2 4
volts isavailable ontilecondensing
section low voltage terminal strip
between "R" a nd "C", "Y" a nd "C", and "0"and "C". Iftheblower does
not o perate, verify 2 4volts between terminals "G" a nd "C" i nthe air
handler. Replace
the thermostat
ifdefective.
Check setting, calibration,
and wiring
Check forloose o rbroken wires a tcompressor,
capacitor,
orcontactor.
Check UPM board r ed default L.E.D. forBlink C ode
Ifthe compressor
iscool and theoverload will n otreset, replace
compressor.
Internal winding g rounded tothecompressor
shell. Replace
compressor.
Ifcompressor
burnout, install suction filter d ryer.
After c ompressor
has c ooled, check continuity ofthecompressor
windings. Ifthe windings are open, replace thecompressor
In"COOLING"
mode: Lack oforinadequate
water flow. Entering water
temperature
istoo warm. Scaled orplugged condenser,
in"HEATING"
mode: Lack o forinadequate
airflow. Blower inoperative,
clogged filter
orrestrictions
induct w ork
The unit i sovercharged
withrefrigerant.
Reclaim refrigerant,
evacuate
and recharge with factor recommended
charge.
Check fordefective orimproperly calibrated
high pressure
switch.
in"COOLING"
mode: Lack oforinadequate
airflow. Entering air
temperature
istoocold. Blower inoperative,
clogged filter or
restrictions
induct w ork. In"HEATING"
mode: Lack oforinadequate
water flow. E ntering water temperature
istoocold. Scaled orplugged
condenser.
The unit i slow onrefrigerant.
Check forrefrigerant
leak, repair,
evacuate
and recharge withfactory recommended
charge.
Check fordefective orimproperly
calibrated
lowpressure
switch.
33