ECM INTERFACE
BOARD
Refer
to Fig. 66, item (12) for ECM
interface
board
location.
In
addition
to providing
a connecting
point for thermostat
wiring,
the
interface
board
also
translates
thermostat
inputs
into
control
commands
for the Electronic
Commutated
Motor
(ECM)
DC fan
motor
and provides
thermostat
signals
to unit's
UPM board.
The
thermostat
connections
and their functions
are as follows:
10
I _
U
jo:3
-[ZZF
F'c;_, W 1 Q)
4==_
EFM
0
CF
AD,UST
1
9
8
7
6
5
(1) Motor Harness Plug
(2) Blower CFM Adjustment
(3) Motor Settings
(4) Dehumidification
Indication
(5) Thermostat
Contact Inputs
(6) CFM Count Indicator
A14124
(7)
Thermostat
Input
Status
Indication
(8)
Reheat
Digital
Outputs
(9)
Thermostat
Outputs
(10)
24 VAC
(11)
Dehumidification
Method
Selector
Fig. 72 - ECM
Interface
Board
NOTE:
CFM
LED
indication
is an
approximation.
Utilize
conventional
Test
and Balance
equipment
for
accurate
airflow
measurement.
• CFM count
indicator
(see Fig. 72, item 6) blinks
to indicate
approximate
airflow
in CFM and may flicker when the unit is off.
• Each blink of the LED represent
approximately
100 CFM of air
delivery
so if the LED blinks
12 times, pauses,
blinks
12 times,
etc. the blower
is delivering
approximately
1200 CFM.
Dehumidification
Mode
Position
the
HGRH
DIP
switch
in the "NO"
(OFF)
position.
When
the switch
is in this position,
upon a dehumidification
call,
the unit will operate
at a lower speed to increase
dehumidification
while
cooling.
See Fig. 73.
HGRH
YES
NO
YI
Y2
G
O
WI
EM/W2
NC
C1
R
H
A14126
Fig. 73 - Dehumidification
Method Selector
Thermostat
Outputs
First Stage Compressor Operation
Second Stage Compressor Operation
Fan
Reversing Valve (energized in cooling)
Auxiliary
Electric Heat (runs in conjunction
with
compressor)
Emergency Heat (electric heat only)
Transformer 24 VAC Common (extra connection)
Transformer 24 VAC Common (primary connection)
Transformer 24 VAC Hot
Dehumidification
Mode
NOTE:
When
the unit is used with
certain
Carrier
and Bryant
thermostats
with Relative
Humidity
control
(including
the Carrier
Edge
TP-PRH01
and
Bryant
Preferred
T6-PHP01)
the
unit's
dehumidification
mode will not be activated
unless
a relay is added
as shown
in Fig. 74.
Relay part number
xxxxxx
is recommended
and
available
through
Replacement
Components.
If
dehumidification
mode
is not required
and these
thermostats
are
used, do not connect
to the "H" terminal.
c
DE HUMIDInCATION CAL
H
:_
COOUNGSTA6EI
¥1
73
COOLING STAGE 2
¥2:3
HEATING STAGE 1
Wl :?
HEATING S TAGE2
W2,E ©
SWITCH OVERVALVE
OB
:3
BLOWER
G
D
24VAC _HOT)
R
D
24VAC_COMMON)
C
?)
'\.j
DHR
,_
c
_,,
H
(
Y2
'-
Wl
c
w2
c
o
c
e
(
R
{
c
ECM
CONTROLLER
INTERFACE
j .......... j
HGRH
YES
NO
COOLING STAGE2
HEATING STAGE 1
HEATING STAGE 2
REWRSIN6 VALW
BLOWER
24VAC
LINE VOLTS
EX 2SOVAC
D
LOWVOLTAGE CLASS IIWIRING 10AWG
DHR
DEHUMIDIFICATION
RELAY
FIELD
INSTALLED
Fig. 74 - Cool to Dehumidify
Application
with ECM
Controller
A14189
25