4.Reinstall
the removed
plastic plugs
in the original
Conden-
sate Drain Location.
5. Route the flexible
plastic tube from FRONT
left corner post
to BACK
left. See Fig. 59.
UNIT
DAMAGE
HAZARD
Failure
to follow
this caution
may
result
in equipment
damage
or improper
operation.
Avoid
kinking
the hose and/or creating
a dip which
could
act as a second
internal
p-trap.
Double
trapped
drain lines
will not drain properly.
6. Measure
and
cut
the
condensate
drain
hose
to
the
appropriate
length.
7. Insert spring
onto condensate
drain hose.
8. Reinstall
condensate
drain plastic
fitting
and bushing
in its
new location.
See Fig. 60.
HRP Switch Relocation
The
HRP
Pump
Disconnect
Switch
is mounted
on front
right
corner post.
See Fig. 61.
)
Fig. 61 - HRP
Pump
Disconnect
Switch
Location
PERSONAL
INJURY
AND/OR
UNIT
DAMAGE
HAZARD
A14094
A14093
Fig. 59 - Route
Plastic Tube
from Front Left to Back Left
Fig. 60 - Relocate
Condensate
Drain
Connection
A14091
Failure
to follow
this caution
may result in personal
iniury
and/or wire damage.
Do
not
route
wiring
over
potentially
hot
surfaces
or
exposed
sharp edges.
m
\
\
)
Fig. 62 - Rectangular
Knockout
Location
A14095