Assembly Replacement
A3 Fan Module
Tools Required
— T-10 driver
Removal Procedure
1. Disconnect the power cord.
2. Remove the outer-cover from the signal generator. Refer to
3. Place the signal generator upside down on a flat surface.
4. Refer to
Figure 3-32
Outer Wall Removal
Keysight Agile Signal Generator Service Guide
on page
99.
Figure
3-32. Using the T-10 driver remove the eleven screws (1)
(0515-1946) that attach the outer wall (2) to the chassis.
"Outer Cover"
135